Test Panel Tooling Test Panel Tool (Option 3)

Adjustable Cavity RTM Test Panel Tool

500 x 500 mm mechanically clamped RTM test panel tool with a sophisticated screw adjustable cavity thickness mechanism.

Features include:

  • The lower mould is fixed with a moveable peripheral flange place which allows depth adjustment
  • The upper face consists of 25 mm heat toughened glass plate in a supporting steel framework to maintain accuracy at positive pressures
  • The upper mould is also available is machined aluminum if upper mould heating or high precision is required
  • Injection is via a peripheral injection gate with a central vent or vice versa
  • The lower mould and peripheral flange can be specified with fluid heating channels or integral electrical heating with the appropriate insulation
  • The glass upper face is hinged and supported on gas struts for ease of operation
  • A high temperature air ejector system is included with standard specification
Tooling Options
Universal Sensor Positions
  • Machined ports in the tool so it can accept an in-mould pressure sensor (IMPS) or thermocouple (T/C)
  • Blanking plugs are included to blank off the machined holes when not in use
  • Up to 4 universal sensor positions are available for IMPS and/or T/C's
  • High Temperature Air Ejector
  • In-mould high temperature air ejector designed to provide maximum air-flow with minimum interference with the mould surface
  • Designed to be fitted into either composite or metal tooling
  • Included as standard with all options
  • 2 Litre Catch-Pot
  • 2 litre inline catch-pot assembly with 1 x GEKA fitting
  • Designed to be used for vacuum connection
  • Included as standard with all options
  • Heating Options
    Fluid Heating
  • Recommended for heating up to 80°C
  • Protective insulation will be required for moulds operating above 50°C

    Fluid heating unit comprising of:

  • Stainless steel braided hoses
  • Temperature control unit with digital display of the set and actual temperature with 1/10 degree to read in °C or °F
  • Water operation heating capacity of 3 kW
  • Pump motor capacity of 0.75 kW
  • Power supply: 400V 50 Hz 16A 3P+N+E
  • Standard Electrical Heating
  • Recommended for heating of up to 180°C
  • Protective insulation will be required for tools operating above 50°C

    Electrical heating unit comprising of:

  • PID temperature controller with K-type thermocouple feedback from the tool
  • Control system to comprise all necessary electrical safety and gear control
  • Numerical display of setpoint and current temperature
  • Power supply: 400V 50 Hz 16A 3P+N+E
  • Advanced Electrical Heating
  • Recommended for heating of up to 180°C
  • Protective insulation will be required for tools operating above 50°C

    Advanced electrical heating unit comprising of:

  • PID temperature controller with K-type thermocouple feedback from the tool
  • Control system to comprise all necessary electrical safety and gear control including a back-up overtemperature protection system
  • 4" touchscreen control with graphs of heater temperatures
  • Controllable ramp rates for heating and cooling
  • USB port for data logging as a standard and the data is logged to CSV format
  • Additional datalogging inputs for IMPS and T/C's options are available
  • Power supply: 400V 50 Hz 16A 3P+N+E
  • How to Specify/Order

    Item/Option NotesPart/Option Number
    500 x 500 mm Adjustable Cavity RTM Test Panel Tool4 bar pressure ratingXM-5103
    Heated Aluminium Upper Mould01
    Options
    Universal Sensor Positions
    Sensor Mounting Detail - One PortOptional machined hole for either IMPS or T/C21
    Sensor Mounting Detail - Two PortsOptional machined holes for either IMPS or T/C22
    Sensor Mounting Detail - Three PortsOptional machined holes for either IMPS or T/C23
    Sensor Mounting Detail - Four PortsOptional machined holes for either IMPS or T/C24

    Heating OptionNotesPart/Option Number
    Options
    Fluid Heating/Temperature Control UnitFor water or oil02
    Electrical Heating: Standard ControlLower tool cavity plate and peripheral flange (2 zones)03-04
    Electrical Heating: Standard Control - Third ZoneRequired if an aluminium upper mould is specified06
    Electrical Heating: Advanced ControlLower tool cavity plate and peripheral flange (2 zones)07-08
    Electrical Heating: Advanced Control - Third ZoneRequired if aluminium upper mould is specified09
    Data Logging Includes:

    Cavity plate heating
    3 x 0-10V IMPS outputs
    3 x Type-K T/C inputs

    Only available for advanced control, electrical heated option

    Does not include the sensors or thermocouples
    31
    Insulation BlanketRequired for moulds operating above 50°C10

    To specify a tooling configuration use the main test panel tool part number, followed by the required option numbers separated by a hyphen:

    e.g. XM-5103-02-07-08-09-10 specifies an Adjustable Cavity RTM Test Panel Tool with a fluid heating and temperature control unit and full advanced control electrical heating